Sample report · simulated sites and data, for illustration only

SolarDoc Pro

Bankability & Site Ranking Report

Prepared for: Example Solar Developer · Portfolio: 3 candidate sites, India · Report date: 2026-11-20

Executive summary

Site A (Kutch, Gujarat) ranks first with a Bankability Score of 96: bankable. Site C has the highest resource, but its data and documentation gaps lower its score. Site B needs 8 actions before financing. Site C needs 5 actions before financing.

Ranking

2score 75Site BBankable with conditions1score 96Site ABankable3score 73Site CBankable with conditions

Where the sites are

10°N15°N20°N25°N30°N70°E75°E80°E85°E90°ETropic of Cancer1Site A2Site B3Site C

Halo size shows how sunny the site is.

Bankability Score by component

Data quality (30)Record length (25)Uncertainty (25)Documentation (20)
0255075100Site AData quality: 29.7 / 30Record length: 25.0 / 25Uncertainty: 25.0 / 25Documentation: 16.0 / 2096Site BData quality: 18.9 / 30Record length: 25.0 / 25Uncertainty: 18.6 / 25Documentation: 12.0 / 2075Site CData quality: 27.0 / 30Record length: 21.3 / 25Uncertainty: 12.9 / 25Documentation: 12.0 / 2073
#1

Site A · Kutch, Gujarat

150 MWp · 23.60°N, 69.90°E · 40 m · Class A thermopile pyranometers and pyrheliometer on a sun tracker

96Bankable

How much sun to bank on

P50 (expected)100%P90, 10-year96%P90, single year96%

Bars are to scale. P50 is 1,992 kWh/m² a year.

Where the uncertainty comes from

±2.9%uncertainty
  • Sensors & data quality51%
  • Short on-site record49%
  • Reference period0%

Paperwork lenders ask for

  • ✓ Current calibration certificates
  • ✓ Cleaning and maintenance log
  • ✓ Station metadata (coordinates, mounting, logger program)
  • ✓ Sensor make, model and class documented
  • ✗ Site photos and horizon survey

Station health

Global pyranometerHealthy✓ Direct-beam sensorHealthy✓ Sun tracker / shade ballAligned✓ Logger clockIn time with the sun✓ ✓✓ Data loggerHealthyPowerNo outages
Jan '24FebMarAprMayJunJulAugSepOctNovDecJan '25Logger clockDirect-beam sensorGlobal pyranometerSun trackerData loggerPower / data gapsHealthy Check Problem

Year-to-year sunshine (15-year reference)

185019001950200020502010: 2001 kWh/m²102011: 1985 kWh/m²2012: 2009 kWh/m²122013: 1980 kWh/m²2014: 1986 kWh/m²142015: 1988 kWh/m²2016: 1989 kWh/m²162017: 1984 kWh/m²2018: 1988 kWh/m²182019: 1998 kWh/m²2020: 1970 kWh/m²202021: 1990 kWh/m²2022: 2002 kWh/m²222023: 2003 kWh/m²2024: 2013 kWh/m²24P50 1992P90 (1-yr) 1918

Long-term data check: the provider's typical-year file

98Ready for a bank report

Typical year, P50, hourly, GHI, DNI and DHI · 1,990 kWh/m² a year · -0.3% against 12 months of station data. Time setting found from the sun: UTC+5:30, with each value stamped at the middle of its period.

Time zone and time stamps OK

Times line up with the sun. The file is in UTC+5:30, with each value stamped at the middle of its period.

Complete year, no gaps OK

A typical year with 8,760 of 8,760 hours.

Enough years behind it OK

Built from about 20 years of data (2005–2024). Long enough to average out good and bad years.

Right kind of year for P50 OK

Labelled as a P50 (average) year: the right input for the P50 estimate.

Stated uncertainty OK

The provider states ±4% on the yearly sum.

Data is for your site OK

File coordinates (23.600, 69.900) match the site.

Physically possible values OK

Every value is within what the sun can physically deliver, and nights are dark.

GHI, DNI and DHI agree OK

Direct and diffuse add up to the total in almost every hour, as they should.

Believable sunshine for the place OK

On average 59% of the sunshine above the atmosphere reaches the ground over the year, which is normal.

Year-to-year spread (for P90) Not known

A typical year hides how much sunshine changes from one year to the next, which the P90 needs. Ask for the full multi-year time series as well.

Agrees with your station OK

Over 12 months, the long-term data is 0.3% lower than your station measured. Within the normal year-to-year spread.

Questions sent to the data provider:

  1. Please also send the full multi-year time series (every year, hour by hour), not only the typical year, and say how much of it is gap-filled.

Data quality findings

No problems found.

Actions to reach "Bankable"

  1. Provide: site photos and horizon survey.
#2

Site B · Bundelkhand, Uttar Pradesh

120 MWp · 25.45°N, 78.60°E · 280 m · Class A thermopile pyranometers and pyrheliometer on a sun tracker

75Bankable with conditions

How much sun to bank on

P50 (expected)100%P90, 10-year95%P90, single year95%

Bars are to scale. P50 is 1,834 kWh/m² a year.

Where the uncertainty comes from

±4.0%uncertainty
  • Sensors & data quality75%
  • Short on-site record25%
  • Reference period0%

Paperwork lenders ask for

  • ✓ Current calibration certificates
  • ✗ Cleaning and maintenance log
  • ✓ Station metadata (coordinates, mounting, logger program)
  • ✓ Sensor make, model and class documented
  • ✗ Site photos and horizon survey

Station health

Global pyranometerReads low in Oct! Direct-beam sensorHealthy✓ Sun tracker / shade ballAligned✓ Logger clock1 hour off, Jun–Aug! !! Data loggerFroze on 12 MarPowerOutage 20 Jul – 24 Jul
Jan '24FebMarAprMayJunJulAugSepOctNovDecJan '25Logger clockDirect-beam sensorGlobal pyranometerSun trackerData loggerPower / data gapsHealthy Check Problem

Year-to-year sunshine (15-year reference)

1650170017501800185019002010: 1821 kWh/m²102011: 1845 kWh/m²2012: 1841 kWh/m²122013: 1814 kWh/m²2014: 1832 kWh/m²142015: 1871 kWh/m²2016: 1857 kWh/m²162017: 1820 kWh/m²2018: 1837 kWh/m²182019: 1811 kWh/m²2020: 1859 kWh/m²202021: 1830 kWh/m²2022: 1830 kWh/m²222023: 1802 kWh/m²2024: 1845 kWh/m²24P50 1834P90 (1-yr) 1737

Long-term data check: the provider's typical-year file

82Usable, after the fixes below

Typical year, P50, hourly, GHI, DNI and DHI · 1,824 kWh/m² a year · +2.9% against 11 months of station data. Time setting found from the sun: UTC, with each value stamped at the middle of its period.

Time zone and time stamps Problem

The header says UTC+5:30, but the sun says the times are UTC. If PVsyst reads it as UTC+5:30, every hour is shifted.

Complete year, no gaps OK

A typical year with 8,760 of 8,760 hours.

Enough years behind it OK

Built from about 17 years of data (2008–2024). Long enough to average out good and bad years.

Right kind of year for P50 OK

Labelled as a P50 (average) year: the right input for the P50 estimate.

Stated uncertainty Not known

No uncertainty figure in the file. The P90 calculation needs it; ask the provider for the uncertainty of the yearly GHI.

Data is for your site OK

File coordinates (25.450, 78.600) match the site.

Physically possible values OK

Every value is within what the sun can physically deliver, and nights are dark.

GHI, DNI and DHI agree OK

Direct and diffuse add up to the total in almost every hour, as they should.

Believable sunshine for the place OK

On average 55% of the sunshine above the atmosphere reaches the ground over the year, which is normal.

Year-to-year spread (for P90) Not known

A typical year hides how much sunshine changes from one year to the next, which the P90 needs. Ask for the full multi-year time series as well.

Agrees with your station OK

Over 11 months, the long-term data is 2.9% higher than your station measured. Within the normal year-to-year spread.

Questions sent to the data provider:

  1. Which time zone are the times in, and is each value stamped at the start, middle or end of its hour?
  2. What is the uncertainty of the yearly GHI (in %) at this site?
  3. Please also send the full multi-year time series (every year, hour by hour), not only the typical year, and say how much of it is gap-filled.

Data quality findings

  • One-hour time shift in some months
  • Sensors drift out of balance in 2024-10
  • GHI reads down to -7.6 W/m² at night (thermal offset)
  • GHI physically possible limit: 14% of checked records fail
  • DHI physically possible limit: 14% of checked records fail

Actions to reach "Bankable"

  1. Correct the one-hour clock shift (Jun–Aug) and set the logger to a fixed standard time with GPS/NTP sync.
  2. Apply a night-time offset correction to GHI and DHI, and fit ventilation units to the pyranometers.
  3. Flag May DNI as soiled; increase cleaning frequency in the dust season and keep a cleaning log.
  4. Exclude DNI/DHI for 3–14 Nov (tracker misalignment) and add a tracker alignment check to the O&M routine.
  5. Gap-fill the 20–24 Jul outage from the long-term reference and add UPS backup to the logger.
  6. Provide: cleaning and maintenance log.
  7. Provide: site photos and horizon survey.
  8. Long-term file: The header says UTC+5:30, but the sun says the times are UTC. If PVsyst reads it as UTC+5:30, every hour is shifted.

℞ Prescription: equipment to prevent these problems

Logger clock shifts by one hour in some months
  • Kipp & Zonen RaZON+Get a quote
    all-in-one solar monitoring system with built-in GPS for time and position
Global pyranometer reading low in some months (soiling, levelling or shading)
  • Kipp & Zonen SMP12Get a quote
    Class A pyranometer with integrated ventilation and heating to keep the dome clean and dry
  • Kipp & Zonen DustIQGet a quote
    soiling monitor that shows when cleaning is due
Sun tracker or shade ball misaligned
  • Kipp & Zonen SOLYS2Get a quote
    sun tracker with GPS, with sun sensor kit for active tracking
  • Kipp & Zonen RaZON+Get a quote
    compact tracker system measuring DNI and DHI
1 outage of a day or more

Solar + battery power supply (UPS) and a cellular / satellite remote-monitoring modem

Large night-time thermal offset on the pyranometers
  • Kipp & Zonen SMP12Get a quote
    Class A pyranometer with integrated ventilation and heating
  • Kipp & Zonen SMP10Get a quote
    Class A smart pyranometer with low thermal offset (pair with a CVF4)
  • Kipp & Zonen CVF4Get a quote
    ventilation unit for existing pyranometers
Logger freezes or electrical spikes

Surge protection and grounding kit; industrial data logger with remote diagnostics

#3

Site C · Deccan Plateau, Karnataka

200 MWp · 14.50°N, 76.40°E · 600 m · Single Class B thermopile pyranometer (GHI only)

73Bankable with conditions

How much sun to bank on

P50 (expected)100%P90, 10-year94%P90, single year93%

Bars are to scale. P50 is 2,019 kWh/m² a year.

Where the uncertainty comes from

±4.9%uncertainty
  • Sensors & data quality63%
  • Short on-site record37%
  • Reference period1%

Paperwork lenders ask for

  • ✓ Current calibration certificates
  • ✓ Cleaning and maintenance log
  • ✗ Station metadata (coordinates, mounting, logger program)
  • ✓ Sensor make, model and class documented
  • ✗ Site photos and horizon survey

Station health

Global pyranometerHealthy✓ Direct-beam sensorNot installed– Sun tracker / shade ballNot installed– Logger clockIn time with the sun✓ ✓✓ Data loggerHealthyPowerNo outages
Apr '24MayJunJulAugSepOctNovDecJan '25Logger clockDirect-beam sensorGlobal pyranometerData loggerPower / data gapsHealthy Check Problem

Year-to-year sunshine (15-year reference)

18001850190019502000205021002010: 2024 kWh/m²102011: 1987 kWh/m²2012: 2026 kWh/m²122013: 2052 kWh/m²2014: 1958 kWh/m²142015: 1987 kWh/m²2016: 2031 kWh/m²162017: 2040 kWh/m²2018: 2021 kWh/m²182019: 2067 kWh/m²2020: 2024 kWh/m²202021: 2022 kWh/m²2022: 2005 kWh/m²222023: 2007 kWh/m²2024: 2032 kWh/m²24P50 2019P90 (1-yr) 1886

Long-term data check: the provider's typical-year file

77Usable, after the fixes below

Typical year, P90, hourly, GHI only · 1,922 kWh/m² a year · -4.3% against 9 months of station data. Time setting found from the sun: UTC+5:30, with each value stamped at the middle of its period.

Time zone and time stamps OK

Times line up with the sun. The file is in UTC+5:30, with each value stamped at the middle of its period.

Complete year, no gaps OK

A typical year with 8,760 of 8,760 hours.

Enough years behind it Check

Only about 8 years of data. Sunshine varies a few percent from year to year, so fewer than 10 years can sit noticeably above or below the true long-term average.

Right kind of year for P50 Check

This is a P90 year (a deliberately poor year). Use it to test the downside, but the P50 energy estimate needs the P50 (average) year.

Stated uncertainty OK

The provider states ±5.5% on the yearly sum.

Data is for your site OK

File coordinates (14.500, 76.400) match the site.

Physically possible values OK

Every value is within what the sun can physically deliver, and nights are dark.

GHI, DNI and DHI agree Not known

Only GHI in the file. Energy software then estimates direct and diffuse itself, which adds uncertainty for tilted modules and trackers. Ask for DNI and DHI too.

Believable sunshine for the place OK

On average 54% of the sunshine above the atmosphere reaches the ground over the year, which is normal.

Year-to-year spread (for P90) Not known

A typical year hides how much sunshine changes from one year to the next, which the P90 needs. Ask for the full multi-year time series as well.

Agrees with your station Check

Over 9 months, the long-term data is 4.3% lower than your station measured. That is more than year-to-year swings usually explain. Check the station, then correct the long-term data to it ("site adaptation").

Questions sent to the data provider:

  1. Which years is the typical year built from? We need at least 10.
  2. Please send the P50 typical year as well (we have the P90).
  3. Please include DNI and DHI, from the same model run as GHI.
  4. Please also send the full multi-year time series (every year, hour by hour), not only the typical year, and say how much of it is gap-filled.
  5. Can the long-term data be corrected with our on-site measurements (site adaptation)?

Data quality findings

  • Cannot cross-check sensors: DNI and DHI not found

Actions to reach "Bankable"

  1. Add DNI and DHI measurement (or a rotating shadowband irradiometer) so sensors can be cross-checked.
  2. Extend on-site measurement to at least 12 months (currently 9) to reduce long-term correction uncertainty.
  3. Provide: station metadata (coordinates, mounting, logger program).
  4. Provide: site photos and horizon survey.
  5. Long-term file: This is a P90 year (a deliberately poor year). Use it to test the downside, but the P50 energy estimate needs the P50 (average) year.

℞ Prescription: equipment to prevent these problems

Only GHI measured: sensors cannot be cross-checked
  • Kipp & Zonen RaZON+Get a quote
    adds DNI and DHI at low cost, so all three components can be cross-checked
  • Kipp & Zonen SOLYS2 + SHP1 + SMP10Get a quote
    reference-grade tracker station
  • Kipp & Zonen SMP3Get a quote
    second smart pyranometer as a redundant GHI check

Appendix: detailed numbers

RankSiteBankabilityStatusP50 GHIP90 10-yrP90 1-yrUncertaintyData qualityMonths on site
1Site A
Kutch, Gujarat
96 Bankable1,9921,9191,918 ±2.9%99 (A)12
2Site B
Bundelkhand, Uttar Pradesh
75 Bankable with conditions1,8341,7391,737 ±4.0%63 (C)12
3Site C
Deccan Plateau, Karnataka
73 Bankable with conditions2,0191,8911,886 ±4.9%90 (A)9

GHI in kWh/m²/yr. P90 10-yr: value exceeded with 90% probability by the 10-year average. P90 1-yr: exceeded in 9 years out of 10.

Uncertainty budget

Site A

Measurement (sensors + data quality)2.0%Long-term correction (site adaptation)2.0%Long-term reference period0.1%Combined (long-term mean)2.9%

Site B

Measurement (sensors + data quality)3.5%Long-term correction (site adaptation)2.0%Long-term reference period0.3%Combined (long-term mean)4.0%

Site C

Measurement (sensors + data quality)3.9%Long-term correction (site adaptation)3.0%Long-term reference period0.3%Combined (long-term mean)4.9%

Method

Product suggestions are independent recommendations; product names are trademarks of their owners.

This sample uses simulated stations and a simulated long-term reference. Real Pro reports use your measurements and a commercial long-term dataset. Automated analysis complements, not replaces, an independent engineer's review.